Today's Hours: 12:00pm - 8:00pm

Search

Filter Applied Clear All

Did You Mean:

Search Results

  • Article
    Kubín V, Jelínková J, Franêk J.
    Zentralbl Bakteriol Orig A. 1977 Jul;238(3):330-5.
    The method of counter-immunoelectrophoresis (CIE) was tested for its applicability to group B streptococcus typing. The results obtained were compared with the typing by the ring precipitin test. Identical antigens and identical hyperimmune typing serum batches had been used in both methods. A large majority of 75 freshly isolated strains were typed identically by both methods. Five strains with a weak antigenic outfit were untypable by the ring precipitin test but were typed by CIE owing to a higher sensitivity of CIE method. Two strains were typable by the precipitin test but not by CIE; an explanation for this phenomenon is lacking. The CIE method in group B typing is specific, rapid, highly sensitive and relatively simple. It requires strict maintenance of standard conditions. The method is economical with respect to manipulation and material, requires small amounts of diagnostic antisera. Potent antisera may be used diluted. Moreover, sera for CIE typing need not be absorbed to remove group B antibodies. CIE method is practicable for group B streptococcus typing, especially in laboratories carrying out routine large scale type identification.
    Digital Access Access Options