Today's Hours: 12:00pm - 8:00pm

Search

Did You Mean:

Search Results

  • Book
    editor, Steven M. Kurtz.
    Contents:
    A primer on UHMWPE / Steven M. Kurtz
    From ethylene gas to UHMWPE component : the process of producing orthopedic implants / Steven M. Kurtz
    Packaging and sterilization of UHMWPE / Steven M. Kurtz
    The origins of UHMWPE in total hip arthroplasty / Steven M. Kurtz
    The clinical performance of UHMWPE hip replacements / Steven M. Kurtz
    Contemporary total hip arthoplasty : hard-on-hard bearings and highly crosslinked UHMWPE / Steven M. Kurtz, Kevin Ong
    The origins and adaptations of UHMWPE for knee replacements / Steven M. Kurtz
    The clinical performance of UHMWPE in knee replacements / Steven M. Kurtz
    The clinical performance of UHMWPE in shoulder replacements / Stefan M. Gabriel
    The clinical performance of UHMWPE in elbow replacements / Judd S. Day
    Applications of UHMWPE in total ankle replacements / Allyson Ianuzzi, Chimba Mkandawire
    The clinical performance of UHMWPE in the spine / Steven M. Kurtz, Marta L. Villarraga, Allyson Ianuzzi
    Highly crosslinked and melted UHMWPE / Orhun K. Muratoglu
    Highly crosslinked and annealed UHMWPE / John H. Dumbleton, Aiguo Wang, Kate Sutton ...[et al.]
    Highly crosslinked UHMWPE doped with vitamin E / Ebru Oral, Orhun K. Muratoglu
    Vitamin-E-blended UHMWPE biomaterials / Steven M. Kurtz, Pierangiola Bracco, Luigi Costa
    Composite UHMWPE biomaterials and fibers / Steven M. Kurtz
    UHMWPE / hyluronan microcomposite biomaterials / Susan P. James, Rachel (Kurkowski) Oldinski, Min Zhang ...[et al.]
    High pressure crystallized UHMWPEs / Anuj Bellare, Steven M. Kurtz
    Compendium of highly crosslinked UHMWPEs / Steven M. Kurtz
    Mechanisms of crosslinking, oxidative degradation and stabilization of UHMWPE / Luigi Costa, Pierangiola Bracco
    In vivo of UHMWPE / Steven M. Kurtz
    Pathophysiologic reactions to UHMWPE wear particles / Marla J. Steinbeck, Ryan M. Baxter, Theresa A. Freeman
    Characterization of physical, chemical, and mechanical properties of UHMWPE / Stephen Spielgelberg
    Tribological assessment of UHMWPE in the hip / Aaron Essner MS, Aiguo Wang
    Tribological assessment of UHMWPE in the knee / Hani Haider
    Characterization of UHMWPE wear particles / Tipper JL., Richards L., Ingham E. ...[et al.]
    Clinical surveillance of UHMWPE using radiographic methods / Charles R. Bragdon
    ESR insights into macroradicals in UHMWPE / M. Shah Jahan
    Fatigue and fracture of UHMWPE / Francisco J. Medel, Jevan Furmanski
    Development and application of the notched tensile test to UHMWPE / Michael C. Sobieraj, Clare M. Rimnac
    Development and application of the small punch test to UHMWPE / Avram A. Edidin
    Nano- and microindentation testing of UHMWPE / Jeremy L. Gilbert, James D. Wernle
    MicroCT analysis of wear and damage in UHMWPE / Daniel MacDonald, Anton Bowden, Steven M. Kurtz
    Computer modeling and simulation of UHMWPE / Anton E. Bowden, Erin Oneida, Jorgen Bergström.
    Digital Access
    Provider
    Version
    ScienceDirect
    Knovel
  • Article
    Grant K, Rodvien R, Mielke CH.
    Thromb Haemost. 1978 Oct 31;40(2):326-34.
    Acute respiratory failure is an often-fatal syndrome of multiple etiologies in which altered factor VIII may be a marker of endothelial disease. 12 women with overwhelming viral pneumonia were studied with serial factor VIII antigen, procoagulant activity, and von Willebrand's factor assays. Antigen levels were elevated (range: 86--1644%) out of proportion to procoagulant activity (range: 35--521% by a one-stage assay), and factor VIII antigen to activity ratios were as high as 16:1. Von Willebrand's factor was normal but correlated best with procoagulant activity. All patients had abnormal antigen patterns on crossed immunoelectrophoresis, with increases in protein of both fast and slow mobility. These changes in factor VIII correlated with the patient's clinical courses.
    Digital Access Access Options